Five-in-one solution, covering the entire dental industry chain.
Greatly reduce the cost of jewelry production.
Innovative channel letter making way.
One-stop solutions to realize quick production and delivery of castings.
An all-in-one software suitable for additive manufacturing
FDM technology slicing software
Efficient and convenient dental digital 3D printing software
DLP/LCD technology slicing software
Channel letter design slicing software
Method1: Tap [Preheat] heat up the extruder to 240℃, after heating is completed, press the air tube joint and pull out the filament guide tube. Check whether the filaments are bent or the filament tip is not smooth, cut the tip smooth and flat, Install the guide tube and filament back, Tap [Load].
Method2: If method 1 is not improving, use an unclogging pin tool to unclog filament.
Method3: If method land method 2 not improving, please replace the nozzle.
Here's a video tutorial you may follow to unchocking Adventurer 3 nozzle.